How to Perform AlinkPlus Programming Via a Permaconn Unit Solution 2000/3000

 

 

Step-by-Step Guide for AlinkPlus Programming

In AlinkPlus, we need to create a panel profile as normal for the panel to be connected to (eg: One Solution 3000  V2.0)


 

To check and manage the connection settings we must go into FILE then COMMUNICATION SETTINGS.


 

You will see as below. 

 

https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/35063340761/original/6G2n6TlJfKVt426qy5NjtW24i1y0RAl53w.jpeg?1573618858


 

We do not need to change the Modem Registry String settings, we can just use the standard ALinkPlus AT Strings.


 

We also need to ensure we are setting connect to VCOM via Modem Port not Direct Link Port.

 

Device Compatibility:

PM45v3, PM35v3 and PM1048 support Bosch 844, 880 and Solution 16 but not Solution 2000/3000

PM54 supports all of the above including Solution 2000/3000

 

https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/35063340762/original/cOqdZ2QSLNAFcXLxqFsHN2XG7krNmQ3yNQ.jpeg?1573618859

 

This guide is for Bosch Solution 2000 and Bosch Solution 3000