How to Use the Outputs on B308 for RSC+ App Output Control
Exploring Output Control Features in B308 for Enhanced RSC+ App Functionality
Bosch Solution 2000 / Bosch Solution 3000 can support 2 x B308 Output Expansion Modules.
Please set the Address Switch of B308 as below:
First B308:
Second B308:
If you want to use the outputs on B308 for RSC+ app control, please set the Event Code for the Outputs to "Remote Control".
Let's take the first Output on B308 to control the Garage Door as an example.
B308 Output 1 |
Item |
Location |
Data |
Event Code |
0646 |
2 |
Event Code |
0647 |
8 |
Polarity |
0648 |
3 |
Time Base |
0649 |
2 |
Time Base Multiplier |
0650 |
0 |
Time Base Multiplier |
0651 |
1 |
You will see "Output 1" on your RSC+ app then you can click on "Output 1" then Turn on/off your Garage Door
.