Power supply | 100-240V~ 50/60Hz or 24-30V DC |
Rated load current | 6A per one channel 9.5A total |
Compatible load types | resistive or incandescent only |
Active element | micro-gap relay μ |
Maximum length of wires | 3 meters |
Recommended wire cross-section area | 0.2–2.0mm2 (24–14 AWG) (depending on load current) |
Operating temperature | 0–35°C |
Ambient humidity | 0–95% RH without condensation |
Radio protocol | Z-Wave (500 series chip) |
Radio frequency band | 868.0–868.6MHz; 869.7–870.0MHz |
Max. transmitting power | +5dBm |
Range | up to 50m outdoors up to 40m indoors (depending on terrain and building structure |
Dimensions (Height x Width x Depth) |
42.5 x 38.25 x 20.3 mm |
Classification of installation and use | Automatic electrical control for use in equipment for household or similar use |
Mode of operation | Type 1.B Action |
Pollution degree | 2 |
Software class | Class A |
Compliance with EU directives | 2011/65/EU 2015/863 2014/53/EU |