Mounting
Undo the two cover screws to remove the front cover from the Backplate.
Fix Backplate to mounting surface using suitable fixings.
Wiring
Route the cable through the access holes in the rear of the Backplate.
Connect control panel PA zone/circuit to the two reed switch terminals inside the PA Button (not polarity conscious) as shown below.
Refit cover to PA Backplate.
To Operate Press both red buttons simultaneously. The indicator will show RED.
To Reset Insert supplied key into front cover and turn clockwise through 90°. Indicator will show Yellow. Remove key.
Note: Remove key from PA button whilst not in use and store carefully
Operation | Double Push |
Material | ABS |
Switch | Reed |
NO/NC Configuration | Both |
Terminals | 5 |
Tamper | None |
Reset | Latch |
Indicator | Yes |
Backlit | No |
Max Voltage | 50v DC |
Max Current | 500mA |
Security Grade | 1 |
Environmental Class | II |
Dimensions (w) x (h) x (d)mm | 62 x 75 x 30 |