Power Requirements
|
Operating Voltage: |
10.0V DC – 14.5V Dc @ 90mA Max |
Voltage Input (Primary Source): |
16-18V AC 50-60Hz – 24VA External Power Adaptor or 220-240V AC to 18V AC 50-60Hz – 24VA Internal Transformer |
Stand-By – Battery (Secondary Source): |
12V DC, 7.2AH sealed rechargeable battery Panasonic LC-P127R2P or equivalent |
Connections
|
Module Connection (RS485 LAN): | Max total LAN length using multi-stranded security cable = 300m; Max total LAN length using 2-pair twisted shielded data cable (Belden 8723) = 1200m. See the manual for complete wiring instructions. |
Programmable Outputs: |
protected open-collector outputs capable of providing a maximum of 500mA (-) each. Outputs are monitored for short and open circuits and can monitor the state of horn speakers and other connected devices. |
Power Output Terminals: | COMM+ - 2.5A high current output for use with onboard outputs, PTC fuse protected. +12V -1A outputs for use with detectors or powering other modules, PTC fuse protected. |
Environmental Considerations
|
Temperature: | -30o to 55oC Operating |
Humidity: | 5% to 85% at 30oC noncondensing |
PCB
|
Fixing Method: |
The CM705B can be mounted in the MW700, MW710, Mw720 or MW730 enclosures using clip-in PCB mounts supplied |
PWA Dimensions: | 235(W) x 85(D) x 40(H)mm |
Warranty: | 3 years |
Bosch Solution: